Slit-lamp (ophthalmic equipment) usage: slanted strategy, reflective system just after st

Post n°2 pubblicato il 19 Giugno 2014 da electronic11
 

 

 

1. approach of slanted

 

Slit-lamp taking 450 positions, front in the microscope observation, that is essentially the most frequently employed strategy. With slanted method can be observed the majority of the lesions, including proliferation Handheld Portable Slit Lamp of conjunctival nipples, conjunctival follicles, trachoma, corneal scarring, corneal foreign physique pigment and Crystal clouds, Crystal capsule opacification. This process was mostly the modify of colour and verify the relevant section to establish the lesion.

 

2. the reflective system

 

When the slit-lamp shines with eyes met behind the front in the cornea, and Crystal polished surface which include front and rear, reflection will occur. Then turn the microscope bracket, the reflected light enters the microscope, when viewed below the microscope, there's a glimpse of an incredibly bright light. Ahead of and soon after moving the microscope can see micro-reflective surface modifications. In the event you turn the slit lamp along with the components so as to change the angle between the microscope illumination without having microscopes are able to attain the objective of reflected light (Note: it need to focus on the reflective surface from the microscope). This system may be applied to check for corneal edema, corneal surface "grain". Corneal epithelial spalling, corneal ulcers heals scars, colored or reflective mirror of the lens anterior capsule and so on.

 

three. the post method

 

Method of focus with slanted, but at this point the viewer not to look at that mirror clear photos, and turn attention towards the IRIS, resulting inside a blurred spot. Turned with observation spot in front of your IRIS portion with the cornea, corneal lesion seems on the background can be noticed inside the light. When corneal neovascularization, or calm, deep foreign body of cornea, corneal depth corneal vascular blood vessels, the Dhamma, and so on. Such illnesses with slanted technique can't be a definitive diagnosis, this law is usually quickly diagnosed.

 

4. technique of diffuse light lighting

Ophthalmic Slit Lamp

Light the way for this law: fractured lighting systems from a big angle oblique projection, though crack full drive, broad exposure, with centralized light or add frosted glass, with low magnification microscope observation. When normal lighting lighting, and frosted glass, with Dim lighting, it really is difficult to observe subtle lesions. Slit illumination, higher concentration Digital Slit Lamp Microscope  of light, too a lot light, do not go on for a long time. So, which might not add frosted glass, then concentrate the light, even though attempting to decrease the concentrated light time. Such strategies using brightness high concentration of slit light and examined using binocular vision at the same time, so checking is quite practical, comfortable, simple to grasp; parts with the observed morphological integrity, icing around the cake. Its mostly applied for inspection of conjunctiva, sclera, cornea, lens, and also other organizations. For example, this technique converts all of the cornea, Iris, lens surfaces complete of observations, plus the icing, and elastic membrane folds immediately after corneal lens, lens vesicle as well as the elderly get full ideas like nuclear morphology than slanted system is superior.

 

five. adjust the Aperture makes use of

 

Once you adjust the aperture size, may well have cracks of distinct lengths are commonly employed to sweep the eye, taking a look at the ocular involvement. Examine the Crystal may well be acceptable to decrease the fracture, like length, as a way to reduce the glare. Tie front mirror or once you check the back in the fundus speak to lens or vitreous, crack length will have to be shortened. Blue light filter for fluorescence observation, green colour filters Ophthalmic Slit Lamp are made use of for observation of blood vessels.

 